By Ali Hassan, Editor, UAE · Updated 11 November 2026
How to Export Server & Switch Hardware Specs for Quotes
Nobody wants to spend a morning at a rack typing inventory by hand. You don’t have to. Before you power anything down, five minutes of copy-paste commands can capture the CPU, memory, drive and module details a buyer needs. This guide shows how to export server and switch hardware specs for buyback on every common platform.
Quick answer: Run the platform’s own inventory command, save the output as text, and send it with serial numbers:show inventoryon Cisco,racadm hwinventoryon Dell, the iLO Redfish API on HPE, anddmidecodepluslshwon Linux.
The cheat sheet
| Platform | Command | What it captures |
|---|---|---|
| Cisco IOS XE / NX-OS | show inventory | Chassis, PSUs, fans, modules: PID and serial |
| Cisco | show version | Model, software release, uptime |
| Dell iDRAC | racadm hwinventory | CPUs, DIMMs, NICs, controllers |
| Dell iDRAC | racadm getsysinfo | Model and service tag |
| Dell iDRAC | racadm raid get pdisks -o | Physical drives |
| HPE iLO | GET /redfish/v1/Systems/1/ | Model, serial, summary |
| Linux | dmidecode -t processor -t memory | CPU model, DIMM size, speed, part number |
| Linux | lscpu, lsblk | CPU stepping, drive models |
Cisco: show inventory to CSV
Turn off paging, then capture the output through your terminal’s session log:
terminal length 0
show version
show inventory
show switch
On Nexus, add show module. To get a CSV, run this small script on the saved text (test it on one device first):
python
import re, sys t = open(sys.argv[1]).read() for n, d, p, v, s in re.findall(r'NAME: "(.*?)", DESCR: "(.*?)"\s*PID: (\S+)\s*,\s*VID: (\S*)\s*,\s*SN: (\S*)', t): print(f'"{n}","{d}",{p},{v},{s}')
Dell and HPE: ask the BMC, not the OS
The BMC reports hardware even when the operating system is dead, which is common with retired servers. For Dell:
racadm --nocertwarn -r IDRAC_IP -u USER -p PASS hwinventory > dell-hwinv.txt
racadm --nocertwarn -r IDRAC_IP -u USER -p PASS getsysinfo > dell-sysinfo.txt
racadm --nocertwarn -r IDRAC_IP -u USER -p PASS raid get pdisks -o > dell-disks.txt
For HPE, use iLO’s Redfish API:
curl -sk -u USER:PASS https://ILO_IP/redfish/v1/Systems/1/ > hpe-system.json
curl -sk -u USER:PASS https://ILO_IP/redfish/v1/Systems/1/Processors/ > hpe-cpu.json
curl -sk -u USER:PASS https://ILO_IP/redfish/v1/Systems/1/Memory/ > hpe-memory.json
Collection URLs return links to each member (every CPU, every DIMM). Follow those links to get the detail. Our HPE server selling guide explains what buyers look for.
Linux: dmidecode and lshw
Run as root. This captures system, CPU, memory, drives and storage or network controllers in one file:
sudo bash -c 'dmidecode -t system -t processor -t memory; lscpu; lsblk -o NAME,MODEL,SIZE,SERIAL; lspci | grep -Ei "raid|ethernet"' > $(hostname)-specs.txt
sudo lshw -short >> $(hostname)-specs.txt
lscpu shows the CPU stepping. See the dmidecode man page for more type options.
Handle the outputs safely
- Use a read-only BMC account and delete it afterwards.
- Strip passwords, IP addresses and hostnames before emailing.
- Clear shell history if you typed credentials.
- Keep serial numbers. Buyers need them.
What to send with the files
Send one text file per device, a rack location list, condition notes (cracked bezel, missing caddy), and a photo of each serial label. Then wipe or destroy data after exporting, never before. Our data destruction process is aligned with NIST SP 800-88.
Ready for a quote?
Send your files to our IT equipment buyback team. For switches, see our Cisco selling guide.